Standard operating procedure
Rotary Hammer Drill
Read this procedure as text

Rotary Hammer Drill: text version
No person shall commence work involving the operation of any tools, plant or equipment unless they have been trained, deemed competent and authorised. All operators shall read, understand and follow this safe work instruction
- Description of work
- Using a Rotary Hammer Drill.
- Potential hazards
- Exposed moving parts and electrical hazard with the potential to cause harm through entanglement, exposure to heat, dust, projectiles and sharp objects. Noise from percussive rotary hammering.
- PPE required
- Eye Protection, Appropriate Footwear, Hearing Protection, Protective Clothing
1. PRE-Operation:
- Task (e.g. Drawings, instructions, specifications etc.) is clearly understood.
- Inspect Drill for current inspection and tags. Untagged equipment is not to be used. (If battery operated ensure the batteries are in good condition and the battery charger has been inspected and the tags are in date.)
- Work area has been checked for services behind/underneath drill points
- Drill bit is tight in chuck and chuck key has been removed (if applicable).
- Work piece is secured.
- Correct drill speed has been set.
- Where necessary, depth stop for drill has been set.
- Correct bit has been selected for material being drilled.
- Identify ON/OFF switch and emergency stop button.
2. Operation:
- Check that drill bit runs 'true' and does not wobble.
- Keep hands clear of rotating chuck and drill tool.
- Back out frequently on deep cuts to clean and cool drill bit.
- Turn off drill before speed settings or bit is changed. Switch off and unplug or remove battery prior to changing bits.
- Exercise caution when removing hot drill bit.
3. POST-Operation:
- Switch off drill before removing waste material from the drill table.
- Make sure good housekeeping practises are in place to minimise dust build-up.
- Return clean drill bit to drill rack.