Standard operating procedure
Petrol Powered Auger Drill
Read this procedure as text

Petrol Powered Auger Drill: text version
No person shall commence work involving the operation of any tools, plant or equipment unless they have been trained, deemed competent and authorised. All operators shall read, understand and follow this safe work instruction
- Description of work
- Using a Petrol-Powered Auger Drill.
- Potential hazards
- Exposed moving parts; combustion engine hazard with the potential to cause harm through entanglement, exposure to heat, dust, projectiles and sharp objects. Noise from engine; high torque, low rev engine causing jamming or biting of drill tool.
- PPE required
- Eye Protection, Appropriate Footwear, Hearing Protection
1. PRE-Operation:
- Task (e.g. Drawings, instructions, specifications etc.) is clearly understood.
- Inspect drill for current inspection and servicing records.
- Ensure drill is fuelled and oiled with correct mix and specification of fuel and oil. Ensure SDS sheet has been read and understood.
- Work area has been checked for services behind/underneath drill points. If drilling into timber ensure no reinforcing or fixings behind drill location. Take into account wood type and potential areas for jamming of bit.
- Ensure drill bit is tight in chuck and chuck key has been removed (if applicable).
- Correct drill speed has been set.
- Where necessary, depth stop for drill has been set.
- Correct bit has been selected for material being drilled.
- Identify ON/OFF switch and emergency stop button.
2. Operation:
- Prime and choke drill as necessary.
- Check that drill bit runs 'true' and does not wobble.
- Keep hands clear of rotating chuck and drill tool.
- Back out frequently on deep drill holes to clean and cool drill bit.
- Turn off drill before speed settings or bit is changed. Switch off drill prior to changing bits.
- Exercise caution when removing hot drill bit.
- Ensure that body is positioned comfortably and operator is able to apply sustained drill pressure without becoming fatigued or straining.
- Ensure that adequate bracing and pressure is applied by operator to control drill in the event of sudden grabbing or jamming of drill bit.
3. POST-Operation:
- Switch off drill before removing bit or waste material from the drill bit and work area.
- Make sure good housekeeping practises are in place to minimise dust/swathe build-up.
- Once work scope complete, ensure drill is refuelled and topped up with oil. If dirty wipe clean.
- Remove drill bit and return to bit case or toll box
- Return clean drill bit to storage area.
Transcribed from the scanned procedure. If the text and the scan differ, the scanned procedure applies.