Skip to content

Standard operating procedure

Oxy Acetylene Equipment

Read this procedure as text
Oxy Acetylene Equipment standard operating procedure, page 1 of 2Oxy Acetylene Equipment standard operating procedure, page 2 of 2

Oxy Acetylene Equipment: text version

No person shall commence work involving the operation of any tools, plant or equipment unless they have been trained, deemed competent and authorised. All operators shall read, understand and follow this safe work instruction

Description of work
Using oxy-acetylene equipment.
Potential hazards
Fire and ultraviolet light hazard with the potential to cause harm through exposure to heat, projectiles, fumes and gases, radiation, sparks and sharp objects.
PPE required
Gloves, Eye Protection, Welding Mask, Appropriate Footwear, Protective Clothing

1. PRE-Operation:

  • Task (e.g. Drawings, instructions, specifications etc.) is clearly understood.
  • Obtain Hot Work permit if required - (Complete risk assessment etc.)
  • Make sure the work area is clean and clear of grease, oil and any other flammable materials.
  • Ensure fire extinguishers and/or fire hose are available and close by.
  • Make sure the gloves, welding heads and all hoses are in good condition, no evidence of perishing or burns/melting.
  • Flash back arresters shall be fitted to both ends of the hoses and inspected regularly.
  • Make sure other work areas are protected from flash, burning, molten materials etc. (Consider the use of screens, welding blankets, solid catch barriers.)
  • Make sure appropriate ventilation is in place prior to use. Beware of oxygen and/or acetylene build up in enclosed areas
  • If required positive cross-flow ventilation should be in place - any gas build up to flow to non-flame/heat areas.
  • Make sure the gloves, welding goggles and other protective equipment are in good condition. Appropriate PPE is to be worn at all times.

2. Operation:

  • Use only a flint lighter to light torch.
  • Keep hands clear of work piece and away from flame. Do not handle hot materials.
  • Make sure machine is correctly set up for gas flow.
  • Never leave the welder running unattended.

3. POST-Operation:

  • Switch off machine and fume extraction (if relevant).
  • Close gas valves.
  • Inspect hoses and equipment prior to putting away.
  • Hang up welding gun and coil up welding hoses. Make sure that there is no strain placed on flash back arrestor connections.
  • Fire watch may be required under some circumstances - external work, hot work permits etc.

Transcribed from the scanned procedure. If the text and the scan differ, the scanned procedure applies.