Skip to content
Completed

Warwick Train Station Fencing

Replacement of the upper and lower level fencing at Warwick train station.

Client
Public Transport Authority
Location
Warwick, WAView on the map
Warwick Train Station Fencing, Warwick

Scope of work

Planning and approvals

  • Site program, detailed JSA and methodology
  • Permits, procurement and a dilapidation report
  • Pedestrian management plan
  • Architectural drawings, with structural engineer review and sign-off
  • BA3 CDC and BA01 submissions
  • Underground service scanning and a feature survey

Design and fabrication

  • 50NB posts with baseplates, capped and powder coated black

Works on site

  • Temporary fencing and pedestrian management, keeping the footpath usable
  • Stone pitching and footpath cut out for pad footings to engineer detail
  • Posts installed with 1400 mm chainmesh fencing and top and bottom rails, to PTA Specification 8880-450-069
  • Stone pitching reinstated, site cleaned and demobilised

Handover

  • Inspection and test plan (ITP) and engineering sign-off
  • PTA entry into service documentation and close-out certificate
  • As-constructed drawings
  • Project management throughout

Photos