Completed
Warwick Train Station Fencing
Replacement of the upper and lower level fencing at Warwick train station.
- Client
- Public Transport Authority
- Location
- Warwick, WAView on the map

Scope of work
Planning and approvals
- Site program, detailed JSA and methodology
- Permits, procurement and a dilapidation report
- Pedestrian management plan
- Architectural drawings, with structural engineer review and sign-off
- BA3 CDC and BA01 submissions
- Underground service scanning and a feature survey
Design and fabrication
- 50NB posts with baseplates, capped and powder coated black
Works on site
- Temporary fencing and pedestrian management, keeping the footpath usable
- Stone pitching and footpath cut out for pad footings to engineer detail
- Posts installed with 1400 mm chainmesh fencing and top and bottom rails, to PTA Specification 8880-450-069
- Stone pitching reinstated, site cleaned and demobilised
Handover
- Inspection and test plan (ITP) and engineering sign-off
- PTA entry into service documentation and close-out certificate
- As-constructed drawings
- Project management throughout